Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2019, 03:28 PM
  • H 0421_H 0420_29072019_085553.mp4

Date
07/29/2019
W/O
777336
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00180
PipeID
P10876
Time
8:28 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6769
Sewer Name
H JOINT OUTFALL H - UNIT 5D
City
MONTEBELLO
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
32
Purpose
Routine Assessment
Project
WO_777336_TV15113_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
H 0421
Downstream MH
H 0420
Dir. of Survey
Downstream
Length Surveyed
496.7 ft.
Total Length
496.7 ft.
Structural Index
3
Structural Quick
3S00
Structural Rating
294
O&M Index
2
O&M Quick
2S11
O&M Rating
197
Overall Index
2
Overall Quick
Overall Rating
491
Pipe schematic from manhole H 0421 to H 0420
MH: H 0421MH: H 0420downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 04210 ft. VC - Vermin Cockroach0 ft. MWL - Water Level, 35 %of cross sectional area3.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.1 ft. MGO - General Observation - MAGNEZIUM H.O COATING THROUGHOUT REACH493.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish493.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish496.7 ft. AMH - Downstream Manhole, Survey Ends - H 0420

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    3.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAGNEZIUM H.O COATING THROUGHOUT REACH

    3.1 ft. - General Observation - MAGNEZIUM H.O COATING THROUGHOUT REACH

Observations (10)

DistanceCodeObservation
496.7AMHH 0420
0MWM
0AMHH 0421
0VC
493.5DAGS
3.1DAGS
3.1SAP
0MWL
493.4SAP
3.1MGOMAGNEZIUM H.O COATING THROUGHOUT REACH

Properties (6)

additional_info
SC378275
custom_field_two
3
customer
LACSD
datetime
2019-07-29T08:28:52-07:00
documentation
PRO PIPE
is_lateral_inspection
false