Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2019, 03:57 PM
  • H 0420_H 0418A _29072019_105635.mp4

Date
07/29/2019
W/O
777336
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00180
PipeID
P10875
Time
8:57 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6769
Sewer Name
H JOINT OUTFALL H - UNIT 5D
City
MONTEBELLO
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
32
Purpose
Routine Assessment
Project
WO_777336_TV15113_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
H 0420
Downstream MH
H 0418A
Dir. of Survey
Downstream
Length Surveyed
1502.3 ft.
Total Length
1502.3 ft.
Structural Index
3
Structural Quick
413{
Structural Rating
1499
O&M Index
2
O&M Quick
3C2{
O&M Rating
665
Overall Index
2
Overall Quick
Overall Rating
2164
Pipe schematic from manhole H 0420 to H 0418A
MH: H 0420MH: H 0418Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - H 04200 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. VC - Vermin Cockroach, within 8 inches of joint: YES0 ft. MGO - General Observation - CONNECTION AT THE MH 9 O'CLOCK2.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.4 ft. MGO - General Observation - MAGNEZIUM H.O COATING THROUGHOUT REACH2.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start593.9 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS705.7 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish - DEBRIS998.2 ft. RPPD - Repair Patch Defective, from 08 to 04 o'clock, within 8 inches of joint: YES - VCP HALF PIPE/ ABANDONED MH1499.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1499.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish1499.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1502.3 ft. AMH - Downstream Manhole, Survey Ends - H 0418A

Observation photos (5)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.4 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - MAGNEZIUM H.O COATING THROUGHOUT REACH

    2.4 ft. - General Observation - MAGNEZIUM H.O COATING THROUGHOUT REACH

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Repair Patch Defective, from 08 to 04 o'clock, within 8 inches of joint: YES - VCP HALF PIPE/ ABANDONED MH

    998.2 ft. - Repair Patch Defective, from 08 to 04 o'clock, within 8 inches of joint: YES - VCP HALF PIPE/ ABANDONED MH

Observations (16)

DistanceCodeObservation
1499.1SSS
1502.3AMHH 0418A
2.4SAP
593.9DSZDEBRIS
0AMHH 0420
1499.2DAGS
998.2RPPDVCP HALF PIPE/ ABANDONED MH
4.9SSS
0MWL
0MWM
2.4MGOMAGNEZIUM H.O COATING THROUGHOUT REACH
0VC
0MGOCONNECTION AT THE MH 9 O'CLOCK
705.7DSZDEBRIS
2.4DAGS
1499.2SAP

Properties (6)

additional_info
SC378275
custom_field_two
3
customer
LACSD
datetime
2019-07-29T08:57:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false