Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 25, 2019, 08:20 AM
  • 01 0256_01 0255_25062019_013701.mp4

Date
06/25/2019
W/O
771921
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00218
PipeID
P01302
Time
1:20 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5587
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_771921_TV01204_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0256
Downstream MH
01 0255
Dir. of Survey
Downstream
Length Surveyed
293.9 ft.
Total Length
293.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412K
O&M Rating
121
Overall Index
2
Overall Quick
Overall Rating
121
Pipe schematic from manhole 01 0256 to 01 0255
MH: 01 0256MH: 01 0255downstream0 ft. MWL - Water Level, 30 %of cross sectional area0 ft. VC - Vermin Cockroach0 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK ACTIVE0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 02562 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start81.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"291.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish293.9 ft. MGO - General Observation - CONNECTION IN MH 3 OCLOCK ACTIVE293.9 ft. AMH - Downstream Manhole, Survey Ends - 01 0255

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
293.9MGOCONNECTION IN MH 3 OCLOCK ACTIVE
0MWL
293.9AMH01 0255
0VC
0MGOCONNECTION IN MH 3 OCLOCK ACTIVE
291.4DAGS
0MWM
81.2TF
2DAGS
0AMH01 0256

Properties (7)

additional_info
SC377546
custom_field_two
3
customer
LACSD
datetime
2019-06-25T01:20:02-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIP LINER