Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 25, 2019, 06:28 AM
  • 01 0251_01 0250_24062019_234212.mp4

Date
06/24/2019
W/O
771921
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00218
PipeID
P01296
Time
11:28 PM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5587
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_771921_TV01204_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
01 0251
Downstream MH
01 0250
Dir. of Survey
Downstream
Length Surveyed
319.5 ft.
Total Length
319.5 ft.
Structural Index
3
Structural Quick
3K2L
Structural Rating
312
O&M Index
2
O&M Quick
2X12
O&M Rating
254
Overall Index
2
Overall Quick
Overall Rating
566
Pipe schematic from manhole 01 0251 to 01 0250
MH: 01 0251MH: 01 0250downstream0 ft. VC - Vermin Cockroach0 ft. AMH - Upstream Manhole, Survey Begins - 01 02510 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH AT 9 AND 3 OCLOCK ACTIVE2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start55.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"81.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"107 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"130.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"156.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"178.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"205.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"218.3 ft. RFJ - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES229.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"257 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"312 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish317 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish319.5 ft. MGO - General Observation - CONNECTION IN MH AT 9 AND 3 OCLOCK ACTIVE319.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0250

Observation photos (5)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES

    218.3 ft. - Roots Fine Joint, from 07 to 08 o'clock, within 8 inches of joint: YES

Observations (25)

DistanceCodeObservation
107TF
312CM
55.9TFA
0VC
2SSS
178.7TF
0AMH01 0251
205.9TFC
2DAE
2CM
317DAE
130.6TF
229.7TF
0MWL
319.5MGOCONNECTION IN MH AT 9 AND 3 OCLOCK ACTIVE
317SSS
257TFC
156.4TFC
2DAGS
81.2TFA
0MWM
218.3RFJ
319.5AMH01 0250
317DAGS
0MGOCONNECTION IN MH AT 9 AND 3 OCLOCK ACTIVE

Properties (6)

additional_info
SC377546
custom_field_two
3
customer
LACSD
datetime
2019-06-24T23:28:01-07:00
documentation
PRO PIPE
is_lateral_inspection
false