- Date
- 06/21/2019
- W/O
- 771921
- Weather
- Dry
- Operator/Surveyor
- J. VARGAS
- Sewer ID
- Z00218
- PipeID
- P01275
- Time
- 2:19 AM
- Certificate
- U-209-8149
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K5589
- Sewer Name
- 01 SOUTH PARK AVENUE TRUNK
- City
- WATTS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_771921_TV01204_JUN2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- 01 0232
- Downstream MH
- 01 0036
- Dir. of Survey
- Downstream
- Length Surveyed
- 302.2 ft.
- Total Length
- 302.2 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2111
- O&M Rating
- 3
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole 01 0232 to 01 0036 Observation photos (2)

1.7 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

223.2 ft. - Lining Failure Wrinkled, from 11 to 01 o'clock, within 8 inches of joint: YES