Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 27, 2019, 02:06 AM
  • J 0009_J 0007 _26072019_010840.mp4

Date
07/26/2019
W/O
777426
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00060
PipeID
P11595
Time
7:06 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6721
Sewer Name
J JOINT OUTFALL J - UNIT 2A
City
HARBOR CITY
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_777426_TV08100_JUL2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
57 in.
Upstream MH
J 0009
Downstream MH
J 0007
Dir. of Survey
Downstream
Length Surveyed
324.9 ft.
Total Length
324.9 ft.
Structural Index
3
Structural Quick
5L3L
Structural Rating
640
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
640
Pipe schematic from manhole J 0009 to J 0007
MH: J 0009MH: J 0007downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - J 00092 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG6.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN122 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - OPEN219 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"323 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 65% MAG323 ft. MGO - General Observation - PEELING AND FLAKING THROUGHOUT323 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324.9 ft. AMH - Downstream Manhole, Survey Ends - J 0007324.9 ft. MGO - General Observation - CONN 9 O'CLOCK @ MH/ACTIVE324.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    6.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
324.9AMHJ 0007
6.8SSS
324.9MGOCONN 9 O'CLOCK @ MH/ACTIVE
122TFOPEN
219TFA
324.9SSS
323SZ65% MAG
24.3TFOPEN
324SRV
0MWL
0MWM
323MGOPEELING AND FLAKING THROUGHOUT
2SAP
2SRV
2SZ65% MAG
0AMHJ 0009
323SAP

Properties (6)

additional_info
SC378220
custom_field_two
3
customer
LACSD
datetime
2019-07-26T19:06:50-07:00
documentation
PROPIPE
is_lateral_inspection
false