Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 18, 2019, 08:48 AM
  • 22 1071_22 1070_18072019_021048.mp4

Date
07/18/2019
W/O
776941
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00812
PipeID
P17442
Time
1:48 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6766
Sewer Name
22 IRWINDALE TRUNK, SECTS 2,3,4,&5
City
IRWINDALE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_776941_TV22043_JUL2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 1071
Downstream MH
22 1070
Dir. of Survey
Downstream
Length Surveyed
382.5 ft.
Total Length
382.5 ft.
Structural Index
3
Structural Quick
3N2K
Structural Rating
348
O&M Index
2
O&M Quick
2N12
O&M Rating
154
Overall Index
2
Overall Quick
Overall Rating
502
Pipe schematic from manhole 22 1071 to 22 1070
MH: 22 1071MH: 22 1070downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 10710 ft. MGO - General Observation - CONNECTION AT MH 4 O'CLOCK/UNKNOWN/POSSIBLE STOP LOG DOWN0 ft. VC - Vermin Cockroach0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG2 ft. MGO - General Observation - 65% MAGNESIUM COATING THROUGHOUT REACH2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 65% MAG82 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start163.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"380 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 65% MAG380.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish380.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish380.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish381 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 65% MAG382 ft. VC - Vermin Cockroach, within 8 inches of joint: YES - @ MH382.5 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK/CAPPED382.5 ft. AMH - Downstream Manhole, Survey Ends - 22 1070382.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK/ACTIVE

Observation photos (4)

  • General Observation - 65% MAGNESIUM COATING THROUGHOUT REACH

    2 ft. - General Observation - 65% MAGNESIUM COATING THROUGHOUT REACH

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    82 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (21)

DistanceCodeObservation
382.5MGOCONNECTION AT MH 3 O'CLOCK/CAPPED
0MWL
381SZ65% MAG
82SSS
2SZ65% MAG
2MGO65% MAGNESIUM COATING THROUGHOUT REACH
2SAP
0AMH22 1071
382VC@ MH
2DAGS
380.1DAGS
0MGOCONNECTION AT MH 4 O'CLOCK/UNKNOWN/POSSIBLE STOP LOG DOWN
163.1TFA
380.1SAP
0VC
382.5AMH22 1070
2SZ65% MAG
380SZ65% MAG
380.1SSS
382.5MGOCONNECTION AT MH 9 O'CLOCK/ACTIVE
0MWM

Properties (6)

additional_info
SC378271
custom_field_two
3
customer
LACSD
datetime
2019-07-18T01:48:04-07:00
documentation
PRO PIPE
is_lateral_inspection
false