- Date
- 08/01/2019
- W/O
- 776941
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00812
- PipeID
- P17429
- Time
- 11:41 PM
- Certificate
- U-115-06022794
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K5949
- Sewer Name
- 22 IRWINDALE TRUNK, SECTS 2,3,4,&5
- City
- IRWINDALE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- RFIR_WO_776941_TV22043_JUL2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 1058
- Downstream MH
- 22 1057
- Dir. of Survey
- Downstream
- Length Surveyed
- 269 ft.
- Total Length
- 269 ft.
- Structural Index
- 3
- Structural Quick
- 513J
- Structural Rating
- 174
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 176
Pipe schematic from manhole 22 1058 to 22 1057 Observation photos (3)

1.1 ft. - Hole, from 04 to 08 o'clock, within 8 inches of joint: YES

2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

240 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start