Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 2, 2019, 06:17 PM
  • 01 0265_01 0264_24062019_044405.mp4

Date
06/02/2019
W/O
771921
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00218
PipeID
P01311
Time
11:17 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5588
Sewer Name
01 SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
RFIR_WO_771921_TV01204_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0265
Downstream MH
01 0264
Dir. of Survey
Downstream
Length Surveyed
339.5 ft.
Total Length
339.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2Z00
O&M Rating
268
Overall Index
2
Overall Quick
Overall Rating
268
Pipe schematic from manhole 01 0265 to 01 0264
MH: 01 0265MH: 01 0264downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION IN MH 9 O'CLOCK/CAPPED0 ft. AMH - Upstream Manhole, Survey Begins - 01 02650 ft. MGO - General Observation - CONNECTION IN MH 3 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. MMC - Material Change, Other (state in comments) - CIPP2 ft. OBZ - Obstacles Other, 0 %of cross sectional area, from 08 to 03 o'clock, Start - SEAM TAPE2.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start153.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN180.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN244.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN337 ft. OBZ - Obstacles Other, 0 %of cross sectional area, from 08 to 03 o'clock, Finish - SEAM TAPE337.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish339.5 ft. AMH - Downstream Manhole, Survey Ends - 01 0264339.5 ft. MGO - General Observation - CONNECTION IN MH 3 O'CLOCK/ACTIVE

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
244.5TFOPEN
337OBZSEAM TAPE
0MWL
337.3DAGS
339.5AMH01 0264
0MGOCONNECTION IN MH 9 O'CLOCK/CAPPED
153.5TFOPEN
2MMCCIPP
339.5MGOCONNECTION IN MH 3 O'CLOCK/ACTIVE
180.6TFOPEN
0AMH01 0265
0MGOCONNECTION IN MH 3 O'CLOCK/ACTIVE
2OBZSEAM TAPE
0MWM
2.2DAGS

Properties (7)

additional_info
SC377545
custom_field_two
3
customer
LACSD
datetime
2019-06-02T11:17:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIP LINER