- Date
- 09/17/2019
- W/O
- 0790965
- Weather
- Dry
- Operator/Surveyor
- SANTIAGO OBREGON
- Sewer ID
- Z00252
- PipeID
- P03479
- Time
- 8:53 AM
- Certificate
- U-1014-06022541
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G8082
- Sewer Name
- 02 DOWNEY-BELLFLOWER DIVERSION TRUNK
- City
- DOWNEY
- Loc. details
- Other
- Location Code
- Z
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 24
- Purpose
- Capital Improvement Program Assesment
- Project
- 20190917SHO_DOWNER_BELLFLOWER_DIVERSION_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 02 0911
- Downstream MH
- 02 0910
- Dir. of Survey
- Downstream
- Length Surveyed
- 390 ft.
- Total Length
- 390 ft.
- Structural Index
- 2
- Structural Quick
- 3424
- Structural Rating
- 21
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 25
Pipe schematic from manhole 02 0911 to 02 0910 Observation photos (2)

21 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

232.3 ft. - Broken, at 02 o'clock, within 8 inches of joint: YES