Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 23, 2019, 11:05 AM
  • Section#2_01 0286_01 0285__9232019__I0248.mp4

Date
09/23/2019
W/O
0793909
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00219
PipeID
P01334
Time
4:05 AM
Certificate
1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0248
Sewer Name
01 STANFORD AVENUE TRUNK
City
WILLOWBROOK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
12
Purpose
Maintenance Related
Project
20190923MDM_STANFORD_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 0286
Downstream MH
01 0285
Dir. of Survey
Downstream
Length Surveyed
296.6 ft.
Total Length
296.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3321
O&M Rating
11
Overall Index
3
Overall Quick
Overall Rating
11
Pipe schematic from manhole 01 0286 to 01 0285
MH: 01 0286MH: 01 0285downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - MH CONN 6:00ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 4:35AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE41.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - STUB53.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB93.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - STUB105.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN138.9 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB146.1 ft. RMJ - Roots Medium Joint, from 08 to 12 o'clock, 25 %, within 8 inches of joint: YESR189 ft. RML - Roots Medium Lateral, from 09 to 12 o'clock, 25 %, within 8 inches of joint: YES189 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE-95% ROOTS191.9 ft. RMJ - Roots Medium Joint, from 08 to 10 o'clock, 10 %, within 8 inches of joint: YESR193.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB214.8 ft. MGO - General Observation - UNUSAL AREAS TOP OF PIPE THROUGHOUT REACH229.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN241.4 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB290.7 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - STUB292.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN296.6 ft. AMH - Downstream Manhole, Survey Ends - 5:00AM

Observation photos (4)

  • Roots Medium Joint, from 08 to 12 o'clock, 25 %, within 8 inches of joint: YESR

    146.1 ft. - Roots Medium Joint, from 08 to 12 o'clock, 25 %, within 8 inches of joint: YESR

  • Roots Medium Lateral, from 09 to 12 o'clock, 25 %, within 8 inches of joint: YES

    189 ft. - Roots Medium Lateral, from 09 to 12 o'clock, 25 %, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE-95% ROOTS

    189 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE-95% ROOTS

  • General Observation - UNUSAL AREAS TOP OF PIPE THROUGHOUT REACH

    214.8 ft. - General Observation - UNUSAL AREAS TOP OF PIPE THROUGHOUT REACH

Observations (21)

DistanceCodeObservation
189RML
41.3TFCSTUB
0MWL
138.9TFCSTUB
105.5TFOPEN
191.9RMJ
53.7TFCSTUB
193.2TFCSTUB
0MGOMH CONN 6:00ACTIVE
214.8MGOUNUSAL AREAS TOP OF PIPE THROUGHOUT REACH
93.8TFCSTUB
0AMH4:35AM
146.1RMJ
0MWM
0MGOMH CONN 9:00 ACTIVE
241.4TFCSTUB
229.4TFOPEN
296.6AMH5:00AM
290.7TFCSTUB
292.8TFOPEN
189TFDACTIVE-95% ROOTS

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2019-09-23T04:05:01-07:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false