Section#3_02 0893_02 0782__9232019__I0247.mp4
1.9 ft. - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, - SLIGHT
1.9 ft. - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, - SLIGHT
1.9 ft. - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES, - HAIRLINE
5.9 ft. - Fracture Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES - SLIGHT
6.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - SLIGHT-JOINT TO JOINT UNDER 3'
8.4 ft. - Upstream Manhole, Survey Ends - 2:35AM STUB
| Distance | Code | Observation |
|---|---|---|
| 4 | TF | OPEN |
| 0 | MWM | — |
| 0 | AMH | 2:25AM |
| 0 | MGO | MH CONN 9:00 ACTIVE |
| 8.4 | AMH | 2:35AM STUB |
| 6.2 | FL | SLIGHT-JOINT TO JOINT UNDER 3' |
| 5.9 | FM | SLIGHT |
| 1.9 | FL | SLIGHT |
| 7.9 | TF | OPEN |
| 1.9 | FL | SLIGHT |
| 1.9 | FC | HAIRLINE |
| 0 | MWL | DRY LINE STOPLOG UPSTREAM |