Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 18, 2019, 06:15 PM
  • D 0075_D 0074_9182019_120339.mp4

Date
09/18/2019
W/O
0792816
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00154
PipeID
P09975
Time
11:15 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8084
Sewer Name
D JOINT OUTFALL D - UNIT 4
City
LAWNDALE
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
20
Purpose
Capital Improvement Program Assesment
Project
20190918DF_JOINT_OUTFALL_D_UNIT_4
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
D 0075
Downstream MH
D 0074
Dir. of Survey
Downstream
Length Surveyed
163.5 ft.
Total Length
163.5 ft.
Structural Index
4
Structural Quick
5231
Structural Rating
15
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
15
Pipe schematic from manhole D 0075 to D 0074
MH: D 0075MH: D 0074downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:20 AM2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start47.1 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start72.8 ft. MGP - General Photograph78.4 ft. MGP - General Photograph159.8 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach159.8 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish159.8 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)159.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish159.8 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish159.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish161.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. ACTIVE163.5 ft. AMH - Downstream Manhole, Survey Ends - 12:25 PM

Observation photos (7)

  • Upstream Manhole, Survey Begins - 11:20 AM

    0 ft. - Upstream Manhole, Survey Begins - 11:20 AM

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    47.1 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    72.8 ft. - General Photograph

  • General Photograph

    78.4 ft. - General Photograph

Observations (17)

DistanceCodeObservation
2SRV
161.4MGOConn. @ Mh, 3 O' Clock. ACTIVE
2SSS
159.8MGOPeeling & Flaking Throughout The Reach
0MWM
159.8SRV
78.4MGP
159.8MGOGREASE THROUGHOUT THE REACH (5%)
0MWL
159.8SAP
163.5AMH12:25 PM
47.1SRC
2SAP
72.8MGP
159.8SRC
159.8SSS
0AMH11:20 AM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-09-18T11:15:22-07:00
documentation
FRANKLIN, BRAR, IGNACIO, RUVALCABA
is_lateral_inspection
false