- Date
- 07/15/2019
- W/O
- 771913
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00234
- PipeID
- P03033
- Time
- 10:28 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6634
- Sewer Name
- 02 ARTESIA EXTENSION TRUNK
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 38
- Purpose
- Routine Assessment
- Project
- RFIR_WO_771913_TV02341_JUN2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 02 0007
- Downstream MH
- 02 0006
- Dir. of Survey
- Downstream
- Length Surveyed
- 342.8 ft.
- Total Length
- 342.8 ft.
- Structural Index
- 3
- Structural Quick
- 433H
- Structural Rating
- 150
- O&M Index
- 2
- O&M Quick
- 4132
- O&M Rating
- 146
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 296
Pipe schematic from manhole 02 0007 to 02 0006 Observation photos (4)

3 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

25.7 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES

101.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

325.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start