29 0322_29 0321 _06182019_011716.mp4
4.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
4.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
21.5 ft. - Fracture Spiral, from 04 to 05 o'clock, within 8 inches of joint: YES
37.2 ft. - Joint Angular Medium
39.7 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
80.7 ft. - Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES
96.2 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES
109.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO
129.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO
134.8 ft. - Fracture Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES, Start
280.4 ft. - Fracture Spiral, from 12 to 02 o'clock, within 8 inches of joint: YES
316.5 ft. - Fracture Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 331.9 | AMH | 29 0322 |
| 330 | DAGS | — |
| 330 | SAM | — |
| 39.7 | SAP | — |
| 331.9 | MGO | SERVICE CONNECTION AT 9 O'CLOCK AT MH |
| 0 | MWL | — |
| 0 | AMH | 29 0321 |
| 4.5 | DAGS | — |
| 37.2 | JAM | — |
| 0 | MGO | SERVICE CONNECTION AT 3 O' CLOCK AT MH |
| 0 | MWM | — |
| 129.6 | FL | — |
| 19.4 | RPR | VCP |
| 109.1 | FL | — |
| 134.8 | FS | — |
| 39.7 | SAM | — |
| 280.4 | FS | — |
| 316.5 | FM | — |
| 80.7 | FS | — |
| 96.2 | FL | — |
| 15.6 | RPR | VCP |
| 266 | FS | — |
| 121.1 | TF | — |
| 4.5 | SAP | — |
| 211.5 | TF | — |
| 21.5 | FS | — |
| 38.4 | TF | — |