Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2019, 07:04 AM
  • Section#4_02 1139_02 1138__9132019__I0235.mp4

Date
09/13/2019
W/O
0787613
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00351
PipeID
P02922
Time
12:04 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0235
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Maintenance Related
Project
20190913VMR_GARFIELD_AVE_EXTENSION_TRUNK
Sewer Type
CB
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1139
Downstream MH
02 1138
Dir. of Survey
Downstream
Length Surveyed
304.7 ft.
Total Length
304.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
312W
O&M Rating
244
Overall Index
2
Overall Quick
Overall Rating
244
Pipe schematic from manhole 02 1139 to 02 1138
MH: 02 1139MH: 02 1138downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01:09 am0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES, Start - Grease1.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES, Start - Grease16.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"84.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"131.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"178.6 ft. RMC - Roots Medium Connection, from 10 to 11 o'clock, 15 %, within 8 inches of joint: YES201.1 ft. RFJ - Roots Fine Joint, at 04 o'clock, within 8 inches of joint: YESR227.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"270.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"289.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"302.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: YES, Finish302.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 08 to 09 o'clock, , within 8 inches of joint: YES, Finish304.7 ft. AMH - Downstream Manhole, Survey Ends - 01:39 am

Observation photos (1)

  • Roots Medium Connection, from 10 to 11 o'clock, 15 %, within 8 inches of joint: YES

    178.6 ft. - Roots Medium Connection, from 10 to 11 o'clock, 15 %, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
0AMH01:09 am
84.1TFC
1.9DAGSGrease
302.1DAGS
16.6TFC
0MWL
304.7AMH01:39 am
1.9DAGSGrease
131.8TFC
270.3TFC
227.1TFC
302.1DAGS
178.6RMC
289.6TFC
0MWM
201.1RFJ

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-09-13T00:04:00-07:00
documentation
REVELES, BRAR
is_lateral_inspection
false