Section#10_01 0223_01 0222__992019__I0229.mp4
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
7.9 ft. - General Observation - 12" NRCP - POSSIBLE 10" NRCP
18.4 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
31 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE
252.4 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG
| Distance | Code | Observation |
|---|---|---|
| 284.5 | TF | OPEN |
| 0 | MGO | MH CONN 3:00 OPEN |
| 0 | MWM | — |
| 2 | SSS | FLAKING CONCRETE |
| 316.7 | SSS | FLAKING CONCRETE |
| 0 | MGO | MH C0NN 9:00 ACTIVE |
| 18.4 | SAM | SEVERE AGG |
| 2 | SAM | SEVERE AGG |
| 79.4 | TF | OPEN |
| 6 | TF | ACTIVE |
| 183.4 | TF | OPEN |
| 316.7 | MGO | MH CONN 9:00 ACTIVE |
| 252.4 | SAM | SEVERE AGG |
| 193.2 | TF | OPEN |
| 316.9 | AMH | 1:10AM |
| 289.8 | TF | OPEN |
| 236.5 | TF | OPEN |
| 316.7 | SAM | SEVERE AGG |
| 31 | SSS | FLAKING CONCRETE |
| 71.5 | MWM | — |
| 0 | AMH | 12:35AM |
| 0 | MWL | — |
| 7.9 | MGO | 12" NRCP - POSSIBLE 10" NRCP |
| 216.3 | TF | OPEN |
| 76.6 | TF | OPEN |