- Date
- 09/05/2019
- W/O
- 0787675
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00202
- PipeID
- P01261
- Time
- 4:19 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0227
- Sewer Name
- 01 COMPTON AVENUE TRUNK
- City
- HUNTINGTON PARK
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- 20190905MDM_COMPTON_AVENUE_TRUNK
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 01 0219
- Downstream MH
- 01 0218
- Dir. of Survey
- Downstream
- Length Surveyed
- 298.7 ft.
- Total Length
- 298.7 ft.
- Structural Index
- 2
- Structural Quick
- 3K2L
- Structural Rating
- 314
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 314
Pipe schematic from manhole 01 0219 to 01 0218 Observation photos (5)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

19.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - FLAKNG CONCRETE

47.2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

232.7 ft. - General Observation - 12" VCP