- Date
- 09/09/2019
- W/O
- 0788181
- Weather
- Dry
- Operator/Surveyor
- IGNACIO
- Sewer ID
- Z00594
- PipeID
- P12630
- Time
- 11:00 AM
- Certificate
- U-115-06022628
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G8074
- Sewer Name
- 15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
- City
- SIERRA MADRE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 01
- Purpose
- Maintenance Related
- Project
- 20190909MI_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
- Material
- NRCP
- Shape
- Circular
- Height
- 9.300000190734863 in.
- Upstream MH
- 15 0852
- Downstream MH
- 15 0851
- Dir. of Survey
- Downstream
- Length Surveyed
- 211 ft.
- Total Length
- 211 ft.
- Structural Index
- 3
- Structural Quick
- 3500
- Structural Rating
- 15
- O&M Index
- 2
- O&M Quick
- 3122
- O&M Rating
- 7
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 22
Pipe schematic from manhole 15 0852 to 15 0851 Observation photos (5)

38.2 ft. - Lining Failure Bulges, from 08 to 04 o'clock, within 8 inches of joint: YES

139.9 ft. - Roots Medium Lateral, from 09 to 11 o'clock, 15 %, within 8 inches of joint: YES

205.1 ft. - Lining Failure Bulges, from 09 to 11 o'clock, within 8 inches of joint: YES

207.7 ft. - Lining Failure Wrinkled, from 08 to 04 o'clock, within 8 inches of joint: YES

210.8 ft. - Lining Failure Defective End, from 09 to 03 o'clock - ROOTS BEHIND LINER