Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 24, 2019, 03:43 PM
  • C 0604_C 0219_7242019_090301.mp4

Date
07/24/2019
W/O
0771869
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00124
PipeID
P09614
Time
8:43 AM
Certificate
U- 415 06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G 8036
Sewer Name
C JOINT OUTFALL C - UNIT 3E
City
LONG BEACH
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
14
Purpose
Capital Improvement Program Assesment
Project
20190724DF_JOINT_OUTFALL_C_UNIT_3E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
C 0219
Downstream MH
C 0604
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole C 0219 to C 0604
MH: C 0219MH: C 0604upstream0 ft. AMH - Upstream Manhole, Survey Ends - 9:07 AM0.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES0.2 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH (5%)0.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2 ft. MWL - Water Level, 35 %of cross sectional area2 ft. MWM - Water Mark, 40 %of cross sectional area2 ft. MGO - General Observation - ROACHES @ MH2.1 ft. AMH - Downstream Manhole, Survey Begins - 8:57 AM

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    1.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (8)

DistanceCodeObservation
1.9SAV
0AMH8:57 AM
1.9MGOGREASE THROUGHOUT THE REACH (5%)
0.1MWL
0.1MWM
2.1AMH9:07 AM
0.1MGOROACHES @ MH
1.9SSS

Properties (6)

additional_info
W.O. ON SCREEN IS WRONG. CORRECT W.O. IS (0771869)
custom_field_two
3
customer
LACSD
datetime
2019-07-24T08:43:08-07:00
documentation
FRANKLIN, IGNACIO, RUVALCABA
is_lateral_inspection
false