- Date
- 07/09/2019
- W/O
- 771897
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00713
- PipeID
- P13842
- Time
- 2:03 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6575
- Sewer Name
- 18 WALNUT WAY TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- RFIR_WO_771897_TV18059_JUN2019
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0025
- Downstream MH
- 18 0026
- Dir. of Survey
- Upstream
- Length Surveyed
- 179.9 ft.
- Total Length
- 179.9 ft.
- Structural Index
- 3
- Structural Quick
- 4C3E
- Structural Rating
- 242
- O&M Index
- 2
- O&M Quick
- 2F00
- O&M Rating
- 72
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 314
Pipe schematic from manhole 18 0025 to 18 0026 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - Surface Aggregate Projecting, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

51.8 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

61 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

70 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start