- Date
- 07/10/2019
- W/O
- 772198
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00749
- PipeID
- P19382
- Time
- 11:53 PM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6631
- Sewer Name
- 20 10TH STREET EAST CONNECTION TRUNK
- City
- PALMDALE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 20
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- RFIR_WO_772198_TV20064_JUN2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 8 in.
- Upstream MH
- 20 0434
- Downstream MH
- 20 0433
- Dir. of Survey
- Downstream
- Length Surveyed
- 326.2 ft.
- Total Length
- 326.2 ft.
- Structural Index
- 3
- Structural Quick
- 3221
- Structural Rating
- 8
- O&M Index
- 2
- O&M Quick
- 2L11
- O&M Rating
- 129
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 137
Pipe schematic from manhole 20 0434 to 20 0433 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

15.1 ft. - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: NO

162.6 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

185.6 ft. - Roots Fine Joint, at 02 o'clock, within 8 inches of joint: YESR

273.2 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES