Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2019, 08:10 AM
  • 05 1268_05 1267 _10072019_012043.mp4

Date
07/10/2019
W/O
771912
Weather
Dry
Operator/Surveyor
J VARGAS
Sewer ID
Z00518
PipeID
P06480
Time
1:10 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6755
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDODO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_771912_TV05332_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1268
Downstream MH
05 1267
Dir. of Survey
Downstream
Length Surveyed
131.5 ft.
Total Length
131.5 ft.
Structural Index
3
Structural Quick
3D21
Structural Rating
71
O&M Index
2
O&M Quick
2D00
O&M Rating
54
Overall Index
2
Overall Quick
Overall Rating
125
Pipe schematic from manhole 05 1268 to 05 1267
MH: 05 1268MH: 05 1267downstream0 ft. MGO - General Observation - ACTIVE DROP CONNECTION AT MH 3 OCLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12680 ft. MWM - Water Mark, 40 %of cross sectional area1.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.8 ft. CS - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES10 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES, Start55.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"63.6 ft. TBI - Tap Break-In Intruding, at 09 o'clock, -, -, within 8 inches of joint: NO, 4", 1" - ROOTS IN LIGHT - OPEN CONNECTION120.2 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 4" - CAP IS CRACKED126.2 ft. CM - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES, Finish130.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish131.5 ft. AMH - Downstream Manhole, Survey Ends - 05 1267131.5 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 OCLOCK

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    1.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

    4.8 ft. - Crack Spiral, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Crack Multiple, from 09 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 09 o'clock, -, -, within 8 inches of joint: NO, 4", 1" - ROOTS IN LIGHT - OPEN CONNECTION

    63.6 ft. - Tap Break-In Intruding, at 09 o'clock, -, -, within 8 inches of joint: NO, 4", 1" - ROOTS IN LIGHT - OPEN CONNECTION

Observations (14)

DistanceCodeObservation
63.6TBIROOTS IN LIGHT - OPEN CONNECTION
55.5TFC
4.8CS
126.2CM
0MGOACTIVE DROP CONNECTION AT MH 3 OCLOCK
120.2TFCCAP IS CRACKED
0MWL
131.5AMH05 1267
1.1DAGS
131.5MGOACTIVE CONNECTION AT MH 9 OCLOCK
10CM
130.3DAGS
0AMH05 1268
0MWM

Properties (6)

additional_info
SC378258
custom_field_two
3
customer
LACSD
datetime
2019-07-10T01:10:17-07:00
documentation
PRO-PIPE
is_lateral_inspection
false