Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 10, 2019, 10:47 AM
  • 05 1262_05 1261 _10072019_040314.mp4

Date
07/10/2019
W/O
771912
Weather
Dry
Operator/Surveyor
J VARGAS
Sewer ID
Z00518
PipeID
P06473
Time
3:47 AM
Certificate
U-209-8148
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6755
Sewer Name
05 SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_771912_TV05332_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 1262
Downstream MH
05 1261
Dir. of Survey
Downstream
Length Surveyed
293.2 ft.
Total Length
293.2 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
150
O&M Index
2
O&M Quick
2V00
O&M Rating
228
Overall Index
2
Overall Quick
Overall Rating
378
Pipe schematic from manhole 05 1262 to 05 1261
MH: 05 1262MH: 05 1261downstream0 ft. MGO - General Observation - OPEN CONNECTION AT MH 9 OCLOCK0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 OCLOCK0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12621.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.9 ft. DSF - Deposits Settled Fine, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start23.1 ft. CM - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES47.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start64.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"72.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"104.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"105.8 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN158.9 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 4"221.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN CONNECTION229.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN CONNECTION273.8 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4" - OPEN CONNECTION289.7 ft. DSF - Deposits Settled Fine, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Finish292.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish293.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1261293.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish293.2 ft. MGO - General Observation - "ZOOMED IN" @ FINISH (GREASE / OBSTRUCTION)

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    1.6 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Deposits Settled Fine,  5 %of cross sectional area, at 06 o'clock,  , within 8 inches of joint: YES, Start

    8.9 ft. - Deposits Settled Fine, 5 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    23.1 ft. - Crack Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    47.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (22)

DistanceCodeObservation
293.2AMH05 1261
0MGOOPEN CONNECTION AT MH 9 OCLOCK
23.1CM
273.8TBOPEN CONNECTION
229.7TBOPEN CONNECTION
1.6DAGS
289.7DSF
0MGOACTIVE CONNECTION AT MH 3 OCLOCK
0MWM
47.2CM
8.9DSF
105.8TBOPEN
292.7CM
0MWL
72.8TFC
104.9TF
0AMH05 1262
158.9TBA
221.7TBOPEN CONNECTION
64.6TFC
293.2DAGS
293.2MGO"ZOOMED IN" @ FINISH (GREASE / OBSTRUCTION)

Properties (6)

additional_info
SC378258
custom_field_two
3
customer
LACSD
datetime
2019-07-10T03:47:06-07:00
documentation
PRO-PIPE
is_lateral_inspection
false