Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2019, 09:19 AM
  • 18 1037_18 1036 _09072019_022710.mp4

Date
07/09/2019
W/O
771793
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00677
PipeID
P14891
Time
2:19 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5929
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_771793_TV18011_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 1037
Downstream MH
18 1036
Dir. of Survey
Downstream
Length Surveyed
122.4 ft.
Total Length
122.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 18 1037 to 18 1036
MH: 18 1037MH: 18 1036downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 103710 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"37.1 ft. FS - Fracture Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES122.4 ft. AMH - Downstream Manhole, Survey Ends - 18 1036

Observation photos (2)

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    10 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES

    37.1 ft. - Fracture Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES

Observations (6)

DistanceCodeObservation
10TF
122.4AMH18 1036
37.1FS
0MWL
0MWM
0AMH18 1037

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-07-09T02:19:19-07:00
documentation
PRO PIPE
is_lateral_inspection
false