Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2019, 08:57 AM
  • 18 1011_18 1010 _08072019_022718.mp4

Date
07/08/2019
W/O
771793
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00677
PipeID
P14865
Time
1:57 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5928
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_771793_TV18011_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1011
Downstream MH
18 1010
Dir. of Survey
Downstream
Length Surveyed
92.3 ft.
Total Length
92.3 ft.
Structural Index
4
Structural Quick
4431
Structural Rating
21
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
21
Pipe schematic from manhole 18 1011 to 18 1010
MH: 18 1011MH: 18 1010downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 101118 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES49.6 ft. FH2 - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES68.7 ft. FM - Fracture Multiple, from 01 to 06 o'clock, within 8 inches of joint: YES71.6 ft. CS - Crack Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES84.4 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES90.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES92.3 ft. AMH - Downstream Manhole, Survey Ends - 18 1010

Observation photos (6)

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    18 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES

    49.6 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 01 to 06 o'clock, within 8 inches of joint: YES

    68.7 ft. - Fracture Multiple, from 01 to 06 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES

    71.6 ft. - Crack Spiral, from 11 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    84.4 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    90.5 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
90.5FL
68.7FM
71.6CS
18FM
49.6FH2
84.4FM
92.3AMH18 1010
0MWM
0MWL
0AMH18 1011

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-07-08T01:57:45-07:00
documentation
PRO PIPE
is_lateral_inspection
false