Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2019, 04:37 AM
  • 18 1005_18 1004 _08072019_221502.mp4

Date
07/08/2019
W/O
771793
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00677
PipeID
P14859
Time
9:37 PM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5929
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_771793_TV18011_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1005
Downstream MH
18 1004
Dir. of Survey
Downstream
Length Surveyed
284.3 ft.
Total Length
284.3 ft.
Structural Index
4
Structural Quick
4634
Structural Rating
36
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
36
Pipe schematic from manhole 18 1005 to 18 1004
MH: 18 1005MH: 18 1004downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 10050 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area17.5 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES23.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"26.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"51.9 ft. FM - Fracture Multiple, from 10 to 06 o'clock, within 8 inches of joint: YES58 ft. FM - Fracture Multiple, from 04 to 05 o'clock, within 8 inches of joint: YES83.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"85.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"99.6 ft. FS - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES144.9 ft. FM - Fracture Multiple, from 04 to 06 o'clock, within 8 inches of joint: YES145.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"151.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"151.5 ft. FS - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: NO210.5 ft. FM - Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES211.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"216.1 ft. CM - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES217.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"267.3 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES270.5 ft. FM - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES271.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"277 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"284.3 ft. AMH - Downstream Manhole, Survey Ends - 18 1004

Observation photos (20)

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    17.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    23.8 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    26.1 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 10 to 06 o'clock, within 8 inches of joint: YES

    51.9 ft. - Fracture Multiple, from 10 to 06 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 04 to 05 o'clock, within 8 inches of joint: YES

    58 ft. - Fracture Multiple, from 04 to 05 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    83.3 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    85.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

    99.6 ft. - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 04 to 06 o'clock, within 8 inches of joint: YES

    144.9 ft. - Fracture Multiple, from 04 to 06 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    145.8 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    151.5 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: NO

    151.5 ft. - Fracture Spiral, from 06 to 10 o'clock, within 8 inches of joint: NO

  • Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES

    210.5 ft. - Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    211.7 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

    216.1 ft. - Crack Multiple, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    217.1 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

    267.3 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

    270.5 ft. - Fracture Multiple, from 12 to 05 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    271.4 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    277 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

Observations (24)

DistanceCodeObservation
58FM
145.8TF
211.7TF
151.5TF
277TF
17.5FM
83.3TF
151.5FS
216.1CM
85.9TF
284.3AMH18 1004
270.5FM
271.4TF
0AMH18 1005
217.1TF
267.3FS
210.5FM
144.9FM
23.8TF
99.6FS
26.1TF
0MWM
51.9FM
0MWL

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-07-08T21:37:30-07:00
documentation
PRO PIPE
is_lateral_inspection
false