Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2019, 07:44 AM
  • 18 1002_18 1001 _09072019_011020.mp4

Date
07/09/2019
W/O
771793
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00677
PipeID
P14856
Time
12:44 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5929
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_771793_TV18011_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1001
Downstream MH
18 1002
Dir. of Survey
Upstream
Length Surveyed
200.8 ft.
Total Length
200.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 18 1001 to 18 1002
MH: 18 1001MH: 18 1002upstream0 ft. AMH - Upstream Manhole, Survey Ends - 18 100249.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"49.1 ft. RML - Roots Medium Lateral, at 10 o'clock, 20 %, within 8 inches of joint: NO115.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"129.5 ft. FS - Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES189.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"194.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"200.8 ft. MWL - Water Level, 30 %of cross sectional area200.8 ft. AMH - Downstream Manhole, Survey Begins - 18 1001200.8 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (6)

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    6.1 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    11.6 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

    71.3 ft. - Fracture Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    85.1 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    151.7 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Roots Medium Lateral, at 10 o'clock, 20 %, within 8 inches of joint: NO

    151.7 ft. - Roots Medium Lateral, at 10 o'clock, 20 %, within 8 inches of joint: NO

Observations (10)

DistanceCodeObservation
0MWL
85.1TF
6.1TF
0AMH18 1001
200.8AMH18 1002
71.3FS
151.7TF
11.6TF
151.7RML
0MWM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-07-09T00:44:29-07:00
documentation
PRO PIPE
is_lateral_inspection
false