Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 9, 2019, 07:15 AM
  • 18 1001_18 1000 _09072019_003146.mp4

Date
07/09/2019
W/O
771793
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00677
PipeID
P14855
Time
12:15 AM
Certificate
U-115-06022794
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K5929
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 1
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Routine Assessment
Project
RFIR_WO_771793_TV18011_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 1001
Downstream MH
18 1000
Dir. of Survey
Downstream
Length Surveyed
145.9 ft.
Total Length
145.9 ft.
Structural Index
3
Structural Quick
4231
Structural Rating
13
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
13
Pipe schematic from manhole 18 1001 to 18 1000
MH: 18 1001MH: 18 1000downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 10010 ft. MWL - Water Level, 10 %of cross sectional area16.5 ft. CM - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES46.5 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Start51.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"52.8 ft. FM - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES57 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"57 ft. MWLS - Water Level, Sag in pipe, 10 %of cross sectional area, Finish102.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"107.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"132.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES145.9 ft. AMH - Downstream Manhole, Survey Ends - 18 1000

Observation photos (8)

  • Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

    16.5 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES

  • Water Level, Sag in pipe, 10 %of cross sectional area, Start

    46.5 ft. - Water Level, Sag in pipe, 10 %of cross sectional area, Start

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    51.3 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

    52.8 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    57 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    102.2 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    107.9 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    132.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
51.3TF
0MWM
145.9AMH18 1000
0AMH18 1001
57TF
107.9TFC
102.2TFC
46.5MWLS
57MWLS
132.2FM
0MWL
52.8FM
16.5CM

Properties (5)

custom_field_two
2
customer
LACSD
datetime
2019-07-09T00:15:08-07:00
documentation
PRO PIPE
is_lateral_inspection
false