18 1001_18 1000 _09072019_003146.mp4
16.5 ft. - Crack Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES
46.5 ft. - Water Level, Sag in pipe, 10 %of cross sectional area, Start
51.3 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"
52.8 ft. - Fracture Multiple, from 07 to 12 o'clock, within 8 inches of joint: YES
57 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"
102.2 ft. - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"
107.9 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"
132.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 51.3 | TF | — |
| 0 | MWM | — |
| 145.9 | AMH | 18 1000 |
| 0 | AMH | 18 1001 |
| 57 | TF | — |
| 107.9 | TFC | — |
| 102.2 | TFC | — |
| 46.5 | MWLS | — |
| 57 | MWLS | — |
| 132.2 | FM | — |
| 0 | MWL | — |
| 52.8 | FM | — |
| 16.5 | CM | — |