Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2019, 11:14 AM
  • 02 1389_02 1388 _01072019_042456.mp4

Date
07/01/2019
W/O
772333
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00242
PipeID
P03907
Time
4:14 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5581
Sewer Name
02 CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_772333_TV02041_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
02 1388
Downstream MH
02 1389
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 02 1388 to 02 1389
MH: 02 1388MH: 02 1389upstream0 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - UNABLE TO FIT TRACTOR0 ft. MGO - General Observation - UNABLE TO FIT TRACTOR AT TURN2 ft. AMH - Downstream Manhole, Survey Begins - 02 13882 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (3)

  • Downstream Manhole, Survey Begins - 02 1388

    0 ft. - Downstream Manhole, Survey Begins - 02 1388

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
2DAE
2DAGS
0AMH02 1388
2MSAUNABLE TO FIT TRACTOR
0MWM
0MWL
2MGOUNABLE TO FIT TRACTOR AT TURN

Properties (6)

additional_info
SC378253
custom_field_two
5
customer
LACSD
datetime
2019-07-01T04:14:00-07:00
documentation
PRO PIPE
is_lateral_inspection
false