Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 2, 2019, 10:23 AM
  • 32 0092A_32 0092_02072019_033458.mp4

Date
07/02/2019
W/O
771997
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00889
PipeID
P19978
Time
3:23 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6624
Sewer Name
32 RYE CANYON TRUNK
City
SANTA CLARITA
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_771997_TV32019_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
10 in.
Upstream MH
32 0092A
Downstream MH
32 0092
Dir. of Survey
Downstream
Length Surveyed
275.1 ft.
Total Length
275.1 ft.
Structural Index
4
Structural Quick
4433
Structural Rating
25
O&M Index
2
O&M Quick
2J00
O&M Rating
108
Overall Index
2
Overall Quick
Overall Rating
133
Pipe schematic from manhole 32 0092A to 32 0092
MH: 32 0092AMH: 32 0092downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 0092A0 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.8 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES171.2 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES181 ft. FM - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES236.3 ft. FS - Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES251.3 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start256.2 ft. FM - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish270.9 ft. FS - Fracture Spiral, from 06 to 08 o'clock, within 8 inches of joint: YES273.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish275.1 ft. AMH - Downstream Manhole, Survey Ends - 32 0092

Observation photos (7)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.8 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    171.2 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    181 ft. - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES

    236.3 ft. - Fracture Spiral, from 05 to 06 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    251.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 06 to 08 o'clock, within 8 inches of joint: YES

    270.9 ft. - Fracture Spiral, from 06 to 08 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
0MWL
256.2FM
251.3FM
0AMH32 0092A
273.4DAGS
2.8FM
181FM
236.3FS
270.9FS
2DAGS
275.1AMH32 0092
0MWM
171.2CM

Properties (6)

additional_info
SC378190
custom_field_two
2
customer
LACSD
datetime
2019-07-02T03:23:20-07:00
documentation
PRO PIPE
is_lateral_inspection
false