Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2019, 08:43 AM
  • 32 0086_32 0084_01072019_015244.mp4

Date
07/01/2019
W/O
771997
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00889
PipeID
P19971
Time
1:43 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K6621
Sewer Name
32 RYE CANYON TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
06
Purpose
Routine Assessment
Project
WO_771997_TV32019_JUN2019
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
32 0086
Downstream MH
32 0084
Dir. of Survey
Downstream
Length Surveyed
246 ft.
Total Length
246 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2I00
O&M Rating
98
Overall Index
2
Overall Quick
Overall Rating
101
Pipe schematic from manhole 32 0086 to 32 0084
MH: 32 0086MH: 32 0084downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 00860 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start54.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"241.2 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES245.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish246 ft. MGO - General Observation - COCKROACHES IN MANHOLE246 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 8 O'CLOCK246 ft. AMH - Downstream Manhole, Survey Ends - 32 0084

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    241.2 ft. - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    246 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
246MGOCOCKROACHES IN MANHOLE
246MGOACTIVE CONNECTION AT MH 8 O'CLOCK
0MWL
245.4DAGS
0AMH32 0086
2DAGS
0MWM
54.9TBA
246AMH32 0084
241.2CM

Properties (6)

additional_info
SC378187
custom_field_two
3
customer
LACSD
datetime
2019-07-01T01:43:25-07:00
documentation
PRO PIPE
is_lateral_inspection
false