Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 12, 2019, 07:36 AM
  • 01 0546_01 0325A_12072019_005549.mp4

Date
07/12/2019
W/O
771785
Weather
Dry
Operator/Surveyor
J. VARGAS
Sewer ID
Z00206
PipeID
P01035
Time
12:36 AM
Certificate
U-209-8149
System Owner
LACSD
Date Cleaned
07/12/19
Pre-Cleaning
No Pre-Cleaning
Media Label
K6759
Sewer Name
01 CROCKETT BOULEVARD-GLEN AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
WO_771785_TV01015_JUN2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
01 0325A
Downstream MH
01 0546
Dir. of Survey
Upstream
Length Surveyed
280.1 ft.
Total Length
280.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0325A to 01 0546
MH: 01 0325AMH: 01 0546upstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 05462.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish11 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"13.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"34.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"36.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"54.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"59.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"80.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"89.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"109.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"112.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"136 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"138.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"153.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish162.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"164.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"185.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"185.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 4"187.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - DEBRIS INSIDE212 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"214.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"235.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"237.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"261.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - DEBRIS INSIDE264.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"268.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start277.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start280.1 ft. AMH - Downstream Manhole, Survey Begins - 01 0325A280.1 ft. VC - Vermin Cockroach280.1 ft. MWL - Water Level, 25 %of cross sectional area280.1 ft. MGO - General Observation - CONNECTION AT MH 3 OCLOCK280.1 ft. MWM - Water Mark, 35 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    11.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (33)

DistanceCodeObservation
94.6TB
45TF
144.1TF
0AMH01 0325A
199.7TF
280.1AMH01 0546
246TF
0VC
18.3TFDEBRIS INSIDE
16TF
243.6TF
0MWL
68.1TF
65.9TF
0MGOCONNECTION AT MH 3 OCLOCK
11.3CM
277.2DAGS
42.3TF
170.5TFC
92.3TFDEBRIS INSIDE
220.3TFC
141.9TF
191TF
266.9TFA
167.9TFC
0MWM
94.9TF
127CM
117.8TF
2.8DAGS
225.9TF
115.2TF
269.1TFC

Properties (6)

additional_info
SC378262
custom_field_two
3
customer
LACSD
datetime
2019-07-12T00:36:56-07:00
documentation
PRO PIPE
is_lateral_inspection
false