Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 11, 2019, 06:30 AM
  • 19 0296_19 0295 SE_11072019_002501.mp4

Date
07/10/2019
W/O
771933
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00718
PipeID
P15188
Time
11:30 PM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6705
Sewer Name
19 ARTESIA-CERRITOS TRUNK
City
ARTESIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_771933_TV19059_JUN2019
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0295 SE
Downstream MH
19 0296
Dir. of Survey
Upstream
Length Surveyed
2.6 ft.
Total Length
2.6 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 19 0295 SE to 19 0296
MH: 19 0295 SEMH: 19 0296upstream0 ft. MSA - Survey Abandoned - VIEW OF THE SIPHON UPLEG FROM D/S MH0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO0 ft. CS - Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: NO2.6 ft. MGP - General Observation - CONNECTIONS AT 11'0, 2'0 AND 3'0 IN MH2.6 ft. MWM - Water Mark, 30 %of cross sectional area2.6 ft. MWL - Water Level, 20 %of cross sectional area2.6 ft. AMH - Downstream Manhole, Survey Begins - 19 02952.6 ft. MGO - General Observation - SE BARREL

Observation photos (1)

  • Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: NO

    2.6 ft. - Crack Spiral, from 08 to 10 o'clock, within 8 inches of joint: NO

Observations (8)

DistanceCodeObservation
0MGPCONNECTIONS AT 11'0, 2'0 AND 3'0 IN MH
2.6MSAVIEW OF THE SIPHON UPLEG FROM D/S MH
2.6DAGS
0MWM
0MWL
0AMH19 0295
0MGOSE BARREL
2.6CS

Properties (6)

additional_info
SC378204
custom_field_two
5
customer
LACSD
datetime
2019-07-10T23:30:27-07:00
documentation
PROPIPE
is_lateral_inspection
false