Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2016, 09:32 AM
  • 14 0963_14 0962_09132016_023311.mp4

Date
09/13/2016
W/O
585470
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00957
PipeID
P23179
Time
2:32 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3756
Sewer Name
14 AVENUE "H" WEST TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
04
Purpose
Routine Assessment
Project
WO_585470_TV14044_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
14 0963
Downstream MH
14 0962
Dir. of Survey
Downstream
Length Surveyed
527.4 ft.
Total Length
527.4 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 14 0963 to 14 0962
MH: 14 0963MH: 14 0962downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 14 09630 ft. MWL - Water Level, 5 %of cross sectional area296.5 ft. CS - Crack Spiral, from 10 to 01 o'clock, within 8 inches of joint: YES527.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE527.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK527.4 ft. AMH - Downstream Manhole, Survey Ends - 14 0962

Observation photos (1)

  • Crack Spiral, from 10 to 01 o'clock, within 8 inches of joint: YES

    296.5 ft. - Crack Spiral, from 10 to 01 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0MWM
0AMH14 0963
296.5CS
527.4MGOCOCKROACHES IN MANHOLE
0MWL
527.4MGOACTIVE CONNECTION AT MH 9 O'CLOCK
527.4AMH14 0962

Properties (6)

additional_info
SC306097
custom_field_two
4
customer
LACSD
datetime
2016-09-13T02:32:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false