Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2016, 10:07 AM
  • 14 0962_14 0961_09132016_025015.mp4

Date
09/13/2016
W/O
585470
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00957
PipeID
P23178
Time
3:07 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3756
Sewer Name
14 AVENUE "H" WEST TRUNK
City
LANCASTER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
04
Purpose
Routine Assessment
Project
WO_585470_TV14044_AUG2016
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
14 0962
Downstream MH
14 0961
Dir. of Survey
Downstream
Length Surveyed
525.9 ft.
Total Length
525.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 14 0962 to 14 0961
MH: 14 0962MH: 14 0961downstream0 ft. AMH - Upstream Manhole, Survey Begins - 14 09620 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area525.9 ft. MGO - General Observation - COCKROACHES IN MANHOLE525.9 ft. AMH - Downstream Manhole, Survey Ends - 14 0961

Observations (6)

DistanceCodeObservation
0AMH14 0962
0MWM
0MGOACTIVE CONNECTION AT MH 9 O'CLOCK
525.9MGOCOCKROACHES IN MANHOLE
0MWL
525.9AMH14 0961

Properties (6)

additional_info
SC306097
custom_field_two
4
customer
LACSD
datetime
2016-09-13T03:07:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false