Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 12, 2016, 11:59 AM
  • G 0207_G 0206_20160112_040242.mp4

Date
01/12/2016
W/O
547459
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z01180
PipeID
P01112
Time
3:59 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3112
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
LYNNWOOD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
WO_547459_TV01053_JAN2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
G 0207
Downstream MH
G 0206
Dir. of Survey
Downstream
Length Surveyed
46.5 ft.
Total Length
46.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole G 0207 to G 0206
MH: G 0207MH: G 0206downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 & 9 OCLOCK0 ft. AMH - Upstream Manhole, Survey Begins - G 02070 ft. MWM - Water Mark, 40 %of cross sectional area6.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Start42.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Finish46.5 ft. AMH - Downstream Manhole, Survey Ends - G 0206

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO, Start

    6.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Start

Observations (7)

DistanceCodeObservation
0MWL
0MGOCONNECTION AT MH 3 & 9 OCLOCK
46.5AMHG 0206
0AMHG 0207
6.1DAGS
0MWM
42.2DAGS

Properties (6)

additional_info
SC224493
custom_field_two
4
customer
LACSD
datetime
2016-01-12T03:59:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false