Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 17, 2016, 10:51 AM
  • H 1432_H 1431 _17082016_035213.mp4

Date
08/17/2016
W/O
585476
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01204
PipeID
P16304
Time
3:51 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3567
Sewer Name
H JOINT OUTFALL H - UNIT 8M
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
WO_585476_TV22034_AUG2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
H 1432
Downstream MH
H 1431
Dir. of Survey
Downstream
Length Surveyed
366.1 ft.
Total Length
366.1 ft.
Structural Index
3
Structural Quick
3500
Structural Rating
15
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
15
Pipe schematic from manhole H 1432 to H 1431
MH: H 1432MH: H 1431downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 14320 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK2.8 ft. MGO - General Observation - MAG COAT 85%22 ft. SAV - Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start28.3 ft. SAV - Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Finish39.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"71.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"77.9 ft. SAV - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: NO102.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"110 ft. SAV - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: YES135.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"166.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"184.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"205.1 ft. SAV - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: NO238.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"300.3 ft. SAV - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: YES312 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"366.1 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK366.1 ft. MGO - General Observation - LATERAL AT MH 3 OCLOCK366.1 ft. AMH - Downstream Manhole, Survey Ends - H 1431

Observation photos (5)

  • Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start

    22 ft. - Surface Aggregate Visible, from 09 to 12 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: NO

    77.9 ft. - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

    110 ft. - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: NO

    205.1 ft. - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: NO

  • Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

    300.3 ft. - Surface Aggregate Visible, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
77.9SAV
39.6TF
2.8MGOMAG COAT 85%
300.3SAV
312TF
366.1MGOLATERAL AT MH 9 OCLOCK
184.4TF
366.1MGOLATERAL AT MH 3 OCLOCK
0MWL
135.6TF
22SAV
0AMHH 1432
102.8TF
0MWM
205.1SAV
166.5TF
28.3SAV
71.3TF
238.7TF
366.1AMHH 1431
255.3TF
0MGOLATERAL AT MH 9 OCLOCK
110SAV

Properties (6)

additional_info
SC305900
custom_field_two
3
customer
LACSD
datetime
2016-08-17T03:51:38-07:00
documentation
PROPIPE
is_lateral_inspection
false