Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 5, 2016, 11:00 AM
  • B 0314_B 0313_20160205_030151.mp4

Date
02/05/2016
W/O
552356
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00088
PipeID
P08839
Time
3:00 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3137
Sewer Name
B JOINT OUTFALL B - UNIT 3B
City
ROSEMEAD, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
21
Purpose
Routine Assessment
Project
WO_552356_TV15105_FEB2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Upstream MH
B 0314
Downstream MH
B 0313
Dir. of Survey
Downstream
Length Surveyed
301.1 ft.
Total Length
301.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K11
O&M Rating
117
Overall Index
2
Overall Quick
Overall Rating
117
Pipe schematic from manhole B 0314 to B 0313
MH: B 0314MH: B 0313downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 03140 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area2 ft. MGO - General Observation - MAGNESIUM H.O. START5.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.8 ft. VC - Vermin Cockroach296.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish301.1 ft. MGO - General Observation - LATERAL AT MH 9 OCLOCK301.1 ft. AMH - Downstream Manhole, Survey Ends - B 0313

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    5.3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
296.7DAGS
0AMHB 0314
2MGOMAGNESIUM H.O. START
301.1MGOLATERAL AT MH 9 OCLOCK
0MWM
8.8VC
5.3DAGS
301.1AMHB 0313
0MWL

Properties (6)

additional_info
SC225524
custom_field_two
4
customer
LACSD
datetime
2016-02-05T03:00:00-08:00
documentation
PRO-PIPE
is_lateral_inspection
false