Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 18, 2016, 10:01 AM
  • B 0342_B 0341_20160218_020141.mp4

Date
02/18/2016
W/O
552355
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00087
PipeID
P08833
Time
2:01 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K3151
Sewer Name
B JOINT OUTFALL B - UNIT 3A RELIEF
City
EL MONTE, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
21
Purpose
Routine Assessment
Project
WO_552355_TV15104_FEB2016
Sewer Type
GRAVITY
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
B 0341
Downstream MH
B 0342
Dir. of Survey
Upstream
Length Surveyed
356.3 ft.
Total Length
356.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole B 0341 to B 0342
MH: B 0341MH: B 0342upstream0 ft. AMH - Upstream Manhole, Survey Ends - B 03420 ft. MGO - General Observation - U/S MANHOLE HAS FLOW GATE203.4 ft. VC - Vermin Cockroach343.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"354.3 ft. MGO - General Observation - MAGNESIUM H.O. START356.3 ft. MWM - Water Mark, 15 %of cross sectional area356.3 ft. AMH - Downstream Manhole, Survey Begins - B 0341356.3 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (2)

  • Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    13.1 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • General Observation - U/S MANHOLE HAS FLOW GATE

    356.3 ft. - General Observation - U/S MANHOLE HAS FLOW GATE

Observations (8)

DistanceCodeObservation
356.3AMHB 0342
152.9VC
13.1TFA
356.3MGOU/S MANHOLE HAS FLOW GATE
0MWM
0AMHB 0341
0MWL
2MGOMAGNESIUM H.O. START

Properties (6)

additional_info
SC225538
custom_field_two
4
customer
LACSD
datetime
2016-02-18T02:01:06-08:00
documentation
PRO-PIPE
is_lateral_inspection
false