Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2016, 12:45 PM
  • 17 0028_17 0027_22022016_044617.mp4

Date
02/22/2016
W/O
552350
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P13751
Time
4:45 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3262
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
06
Purpose
Routine Assessment
Project
WO_552350_TV17001_FEB2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Other
Height
21 in.
Upstream MH
17 0027
Downstream MH
17 0028
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 17 0027 to 17 0028
MH: 17 0027MH: 17 0028upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES0 ft. AMH - Upstream Manhole, Survey Ends - 17 0028, VIEW OF MOUTH OF PIPE, CONDITIONS DO NOT CHANGE.2 ft. MWL - Water Level, 15 %of cross sectional area2 ft. AMH - Downstream Manhole, Survey Begins - 17 00272 ft. MWM - Water Mark, 40 %of cross sectional area

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

  • Upstream Manhole, Survey Ends - 17 0028, VIEW OF MOUTH OF PIPE, CONDITIONS DO NOT CHANGE.

    2 ft. - Upstream Manhole, Survey Ends - 17 0028, VIEW OF MOUTH OF PIPE, CONDITIONS DO NOT CHANGE.

Observations (5)

DistanceCodeObservation
0MWL
2DAGS
2AMH17 0028, VIEW OF MOUTH OF PIPE, CONDITIONS DO NOT CHANGE.
0AMH17 0027
0MWM

Properties (6)

additional_info
SC225484
custom_field_two
4
customer
LACSD
datetime
2016-02-22T04:45:35-08:00
documentation
PRO PIPE
is_lateral_inspection
false