Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 23, 2016, 08:52 AM
  • 17 0035_17 0034_23022016_005433.mp4

Date
02/23/2016
W/O
552350
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00668
PipeID
P13758
Time
12:52 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3263
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
06
Purpose
Routine Assessment
Project
WO_552350_TV17001_FEB2016
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Other
Height
18 in.
Upstream MH
17 0035
Downstream MH
17 0034
Dir. of Survey
Downstream
Length Surveyed
233.4 ft.
Total Length
233.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
4122
O&M Rating
12
Overall Index
2
Overall Quick
Overall Rating
15
Pipe schematic from manhole 17 0035 to 17 0034
MH: 17 0035MH: 17 0034downstream0 ft. AMH - Upstream Manhole, Survey Begins - 17 00350 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 6 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start27.5 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR39.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES45.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"118.5 ft. RFC - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES118.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"137 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR148.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"178.7 ft. RFC - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES178.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"186.5 ft. MWL - Water Level, 40 %of cross sectional area186.5 ft. MWM - Water Mark, 70 %of cross sectional area229.7 ft. MWM - Water Mark, 35 %of cross sectional area229.7 ft. MWL - Water Level, 20 %of cross sectional area232.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish233.4 ft. AMH - Downstream Manhole, Survey Ends - 17 0034

Observation photos (7)

  • General Observation - ACTIVE CONNECTION AT MH 6 O'CLOCK

    0 ft. - General Observation - ACTIVE CONNECTION AT MH 6 O'CLOCK

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR

    27.5 ft. - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    39.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

    118.5 ft. - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR

    137 ft. - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR

  • Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

    178.7 ft. - Roots Fine Connection, from 01 to 03 o'clock, within 8 inches of joint: YES

Observations (20)

DistanceCodeObservation
0AMH17 0035
118.5RFC
137RFJ
178.7RFC
148.3TFC
229.7MWM
229.7MWL
233.4AMH17 0034
232.7DAGS
27.5RFJ
2DAGS
45.8TF
0MWM
178.7TFA
0MGOACTIVE CONNECTION AT MH 6 O'CLOCK
186.5MWL
0MWL
186.5MWM
118.5TFA
39.6CM

Properties (6)

additional_info
SC225486
custom_field_two
4
customer
LACSD
datetime
2016-02-23T00:52:04-08:00
documentation
PRO PIPE
is_lateral_inspection
false