17 0041_17 0040_18022016_021443.mp4
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start
77.7 ft. - Roots Medium Connection, from 01 to 03 o'clock, 10 %, within 8 inches of joint: YES
200.4 ft. - Roots Medium Lateral, from 12 to 03 o'clock, 10 %, within 8 inches of joint: NO
200.4 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: NO, 6" - ROOTS
| Distance | Code | Observation |
|---|---|---|
| 77.7 | RMC | — |
| 200.4 | RML | — |
| 2 | DAGS | — |
| 373.6 | DSZ | — |
| 373.6 | DAGS | — |
| 6.7 | TFA | — |
| 200.4 | TFD | ROOTS |
| 77.7 | TFA | — |
| 45.9 | TBA | — |
| 0 | MWL | — |
| 2 | DSZ | — |
| 376.1 | AMH | 17 0040 |
| 0 | AMH | 17 0041 |
| 134.6 | TFA | — |
| 376.1 | MGO | ACTIVE CONNECTION AT MH 9 O'CLOCK |
| 0 | MWM | — |