- Date
- 05/30/2019
- W/O
- 766493
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00228
- PipeID
- P01792
- Time
- 2:23 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K6555
- Sewer Name
- 01 WRIGHT ROAD TRUNK
- City
- BELL
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 08
- Purpose
- Routine Assessment
- Project
- WO_766493_TV01251_MAY2019
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 24 in.
- Upstream MH
- 01 0955
- Downstream MH
- 01 0954
- Dir. of Survey
- Downstream
- Length Surveyed
- 275.7 ft.
- Total Length
- 275.7 ft.
- Structural Index
- 2
- Structural Quick
- 312D
- Structural Rating
- 49
- O&M Index
- 2
- O&M Quick
- 2J00
- O&M Rating
- 108
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 157
Pipe schematic from manhole 01 0955 to 01 0954 Observation photos (4)

2.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

60.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

164.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

203.6 ft. - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES