- Date
- 05/03/2019
- W/O
- 761820
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00598
- PipeID
- P12255
- Time
- 1:47 AM
- Certificate
- U-111-11880
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K6522
- Sewer Name
- 15 BALDWIN PARK TRUNK
- City
- INDUSTRY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 29
- Purpose
- Routine Assessment
- Project
- WO_761820_TV15019_APR2019
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- 15 0329
- Downstream MH
- 15 0328
- Dir. of Survey
- Downstream
- Length Surveyed
- 402.6 ft.
- Total Length
- 402.6 ft.
- Structural Index
- 3
- Structural Quick
- 3222
- Structural Rating
- 10
- O&M Index
- 3
- O&M Quick
- 4122
- O&M Rating
- 8
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 18
Pipe schematic from manhole 15 0329 to 15 0328 Observation photos (3)

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start