Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 29, 2017, 10:15 AM
  • F 0126_F 0125 _11292017_021540.mp4

Date
11/29/2017
W/O
673962
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00042
PipeID
P10258
Time
2:15 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5232
Sewer Name
F JOINT OUTFALL F - UNIT 6
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
34
Purpose
Routine Assessment
Project
WO_673962_TV02160_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
F 0126
Downstream MH
F 0125
Dir. of Survey
Downstream
Length Surveyed
241.1 ft.
Total Length
241.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2H00
O&M Rating
94
Overall Index
2
Overall Quick
Overall Rating
94
Pipe schematic from manhole F 0126 to F 0125
MH: F 0126MH: F 0125downstream0 ft. AMH - Upstream Manhole, Survey Begins - F 01260 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start57.5 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"104.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"153 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"239.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish241.1 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK241.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE241.1 ft. AMH - Downstream Manhole, Survey Ends - F 0125

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
241.1MGOACTIVE CONNECTION AT MH 3 O'CLOCK
239.3DAGS
241.1MGOCOCKROACHES IN MANHOLE
241.1AMHF 0125
153TFA
0AMHF 0126
0MWM
104.6TFA
0MGOCOCKROACHES IN MANHOLE
0MWL
2DAGS
57.5TFA

Properties (6)

additional_info
SC346403
custom_field_two
4
customer
LACSD
datetime
2017-11-29T02:15:22-08:00
documentation
PRO PIPE
is_lateral_inspection
false