Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 30, 2017, 10:39 AM
  • F 0144B_F 0144A _11302017_024939.mp4

Date
11/30/2017
W/O
673962
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00042
PipeID
P10279
Time
2:39 AM
Certificate
U-111-11880
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5233
Sewer Name
F JOINT OUTFALL F - UNIT 6
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
34
Purpose
Routine Assessment
Project
WO_673962_TV02160_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
F 0144A
Downstream MH
F 0144B
Dir. of Survey
Upstream
Length Surveyed
300.6 ft.
Total Length
300.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
118
Pipe schematic from manhole F 0144A to F 0144B
MH: F 0144AMH: F 0144Bupstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Ends - F 0144B3.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish298.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start300.6 ft. AMH - Downstream Manhole, Survey Begins - F 0144A300.6 ft. MGO - General Observation - COCKROACHES IN MANHOLE300.6 ft. MWL - Water Level, 20 %of cross sectional area300.6 ft. MWM - Water Mark, 30 %of cross sectional area

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
297.5DAGS
2DAGS
0AMHF 0144A
300.6MGOCOCKROACHES IN MANHOLE
0MGOCOCKROACHES IN MANHOLE
0MWL
300.6AMHF 0144B
0MWM

Properties (6)

additional_info
SC346404
custom_field_two
4
customer
LACSD
datetime
2017-11-30T02:39:43-08:00
documentation
PRO PIPE
is_lateral_inspection
false