Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 31, 2019, 08:40 AM
  • 02 2422_02 2105 _01312019_004954.mp4

Date
01/31/2019
W/O
745535
Weather
Dry
Operator/Surveyor
E.RUIZ
Sewer ID
Z00283
PipeID
P04207
Time
12:40 AM
Certificate
U-715-07000753
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6374
Sewer Name
02 MONTEBELLO INTERCEPTOR TRUNK, SECTS 1&2
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_745535_TV02214_JAN2019
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
02 2422
Downstream MH
02 2105
Dir. of Survey
Downstream
Length Surveyed
24.5 ft.
Total Length
24.5 ft.
Structural Index
4
Structural Quick
5333
Structural Rating
24
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
28
Pipe schematic from manhole 02 2422 to 02 2105
MH: 02 2422MH: 02 2105downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 24220 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area3.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start9.7 ft. H - Hole, at 12 o'clock, within 8 inches of joint: YES14.9 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish15 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start18.2 ft. H - Hole, from 10 to 02 o'clock, within 8 inches of joint: YES24.4 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish24.5 ft. AMH - Downstream Manhole, Survey Ends - 02 2105

Observation photos (4)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Hole, at 12 o'clock, within 8 inches of joint: YES

    9.7 ft. - Hole, at 12 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    15 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Hole, from 10 to 02 o'clock, within 8 inches of joint: YES

    18.2 ft. - Hole, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (10)

DistanceCodeObservation
9.7H
0AMH02 2422
18.2H
24.5AMH02 2105
15SRV
0MWL
14.9SAP
3.9SAP
24.4SRV
0MWM

Properties (6)

custom_field_two
1
customer
LACSD
datetime
2019-01-31T00:40:55-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
30160