Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 28, 2019, 04:14 PM
  • 16 0185_16 0184_8282019_092653.mp4

Date
08/28/2019
W/O
PENDING
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00645
PipeID
P13228
Time
9:14 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G8067
Sewer Name
16 ARROYO SECO TRUNK, SECTION 2
City
SOUTH PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
20190828SHO_ARROYO_SECO_TRUNK_SECTION_2
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
16 0184
Downstream MH
16 0185
Dir. of Survey
Upstream
Length Surveyed
175.8 ft.
Total Length
175.8 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 16 0184 to 16 0185
MH: 16 0184MH: 16 0185upstream0 ft. AMH - Upstream Manhole, Survey Ends - MH 01850 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish0 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish35.3 ft. SSS - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - VERY MINOR SPALLING72 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"102.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"172.8 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start172.8 ft. MGO - General Observation - 20% MAG COAT INTACT175.8 ft. MWL - Water Level, 5 %of cross sectional area175.8 ft. AMH - Downstream Manhole, Survey Begins - MH 0184175.8 ft. MWM - Water Mark, 10 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    3 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - VERY MINOR SPALLING

    140.5 ft. - Surface Spalling, from 07 to 05 o'clock, within 8 inches of joint: YES, Start - VERY MINOR SPALLING

Observations (11)

DistanceCodeObservation
3SAV
73.3TFA
175.8AMHMH 0185
175.8SSS
140.5SSSVERY MINOR SPALLING
0MWL
103.8TFC
0AMHMH 0184
175.8SAV
3MGO20% MAG COAT INTACT
0MWM

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2019-08-28T09:14:56-07:00
documentation
OBREGON, YOUNG, CASTILLO, RUVALCABA
is_lateral_inspection
false