Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 3, 2019, 10:52 AM
  • 18 0284_18 0283 _06032019_041610.mp4

Date
06/03/2019
W/O
766532
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00702
PipeID
P14112
Time
3:52 AM
Certificate
U-109-7984
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K6068
Sewer Name
18 SHOEMAKER AVENUE TRUNK
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
30
Purpose
Routine Assessment
Project
WO_766532_TV18178_MAY2019
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0284
Downstream MH
18 0283
Dir. of Survey
Downstream
Length Surveyed
333.5 ft.
Total Length
333.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 18 0284 to 18 0283
MH: 18 0284MH: 18 0283downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 02840 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - MAGNEZIUM H.O COATING start28.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"31.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"78.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"80.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"125.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"180.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"184 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"229.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"232.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"281.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"284 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"331.2 ft. MGO - General Observation - MAGNEZIUM H.O COATING finish333.4 ft. MGO - General Observation - CONNECTIONS AT BOTH 3 AND 9 O' CLOCK AT MH333.5 ft. AMH - Downstream Manhole, Survey Ends - 18 0283

Observations (19)

DistanceCodeObservation
331.2MGOMAGNEZIUM H.O COATING finish
281.4TFC
80.1TFC
0AMH18 0284
184TFC
180.5TFC
333.5AMH18 0283
28.3TFC
2MGOMAGNEZIUM H.O COATING start
0MWM
125.6TFC
232.8TFC
0MWL
31.4TFC
284TFC
229.4TFC
78.1TFC
128.6TFC
333.4MGOCONNECTIONS AT BOTH 3 AND 9 O' CLOCK AT MH

Properties (6)

additional_info
SC377912
custom_field_two
3
customer
LACSD
datetime
2019-06-03T03:52:16-07:00
documentation
PRO PIPE
is_lateral_inspection
false